Some Frequently asked questions:

What is the difference between the BD and EL series Load Bank?
Do you manufacture AC Load Banks?
Do your Load Banks have a timer option?
Can I use the Data Logger by itself?
Can I use 2 or more of your Load Banks in series or parallel?
Can I select any current in steps?
Will the EL series Load Bank work with the Voltage in my country?
Does the LVD have set Voltages or can I select my own?
Can I Rack-mount my Load Bank?

What is the difference between the BD and EL series Load Bank?

Basically The BD series Load Bank is powered by the equipment being tested(eg. batteries) and the EL series Load Bank is powered by mains.
The BD series Load Bank is designed for testing batteries.
The EL series Load Bank is designed for testing rectifiers.

Do you manufacture AC Load Banks?

At this time we do not manufacture AC Load Banks

Do your load banks have a timer option?

We have an option for a timer module, please let us know if you are interested in this when you make your enquiry. Our DLM series data logger can also provide this function when used with our load banks.

Can I use the Data Logger by itself?

Yes, our DLM series Data Logger can be used as a stand-alone unit to monitor Voltages on a battery string, rectifier, fuel cell, or any other source of DC power.

Can I use 2 or more of your Load Banks in series or parallel?

Two or more Load Banks may be used in parallel as long as they are both designed to work on the same Voltage. For example a BD12-48P can be used in parallel with an EL15-48M, just remember that the EL Series will require a source of AC power in order to run.
The Load Banks can not be used in series for higher Voltages.

Can I select any current in steps?

You may select any current within the range of the Load Bank, however our Load Banks have the advantage over many other Load Banks bacause the current is "continuously variable" meaning that the current is not limited to steps of a set value. The current can be set to any value of your choice and adjusted at any time during a test.

Will the EL series Load Bank work with the Voltage in my country?

Previously we would set up each EL Load Bank to work using only the Voltage specified by the customer when an order was placed, New EL Load Banks that are based on our updated design will be able to be used in any country using 110-230V @ 50-60Hz.

Does the LVD have set Voltages or can I select my own?

The LVD (Low Voltage Drop-out) system can be designed to meet your requirements, just let us know what Voltages you would like when you place your order.
If you use one of our DLM series Data Loggers then you can, effectively, set any LVD that you need, either set any overall battery string Voltage or any cell Voltage.

Can I Rack-mount my Load Bank?

We provide an option for rack-mounting all of our products, just let us know if you would like to have your unit rack-mounted and we can arrange this for you. This option needs to be selected at the time of ordering. We do not currently offer an option to retro-fit our Load Banks for this.


 



 
 
BD Series
Battery Discharge 12kW , 15kW and 18kW
BD12-48P

BD12-48P-24/12

BD12-24P
BD12-24P-12
BD12-110P
BD12-110P-48/24

BD15-48P

BD15-48P-24/12

BD18-48P

BD18-48P-24/12

BD12-CUSTOM
EL12 Series
Rectifier Test 12kW, 15kW and 18kW
EL12-48M
EL12-24M

EL12-110M

EL15-48M
EL18-48M
EL12-CUSTOM
EL08 Series
Rectifier Test 8kW
EL08-230M  
EL08-460M  
PT04 Series
Rectifier Test 4kW
PT04-48
PT04-110
PT04-250-63
PT04-FC
PT04-CUSTOM
DLM Series
Data Logger
DLM-09
   
   
 